logo
제품 소개디지털 방식으로 ph-미터

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

인증
중국 SHEN ZHEN YIERYI Technology Co., Ltd 인증
중국 SHEN ZHEN YIERYI Technology Co., Ltd 인증
제가 지금 온라인 채팅 해요

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

큰 이미지 :  PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

제품 상세 정보:
원래 장소: 중국 광둥
브랜드 이름: YIERYI
모델 번호: PHS-3C
결제 및 배송 조건:
최소 주문 수량: 2
가격: AED 145.76-152.27

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

설명
Ph 범위: 0.00-14.00pH 온도 범위: 0-100℃
pH 결의안: 0.01pH 온도 분해능: 0.1℃
pH 정확도: ±0.02pH 온도 정확도: ±0.5℃
PH 디스플레이: 4 디지털 LED 온도 디스플레이: 3- 디지털 LED
온도 보상: 0C-50C 작동 온도: 0C-50C
보정 포인트: 2 점 계측기 타입: 자동 버퍼 인식
전원공급장치: 라벨에 모델 번호: PHS-3C
제품 유형: 물 품질 분석기
강조하다:

Auto Calibration Digital PH Meter

,

0-14.00PH Range Water Quality Analyzer

,

2 Points Calibration Acidity Meter

PHS-3C Auto Calibration Acidity Meter Water Quality Analyzer
Product Specifications
Specification Details
Customized Support OEM
Place of Origin China, Guangdong
Brand Name YIERYI
Model Number PHS-3C
Product Name PH Meter
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 0 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 1
Technical Specifications
  • Range: PH: 0.00-14.00PH, Temperature: 0-100℃
  • Resolution: PH: 0.01PH, Temperature: 0.1℃
  • Accuracy: PH: ±0.02PH, Temperature: ±0.5℃
  • Display: PH: 4-digital LED, Temperature: 3-digital LED
  • Automatic temperature compensation: 0℃-50℃
  • Power supply: As specified on the label
  • Working temperature: 0℃-50℃
  • Calibration: 2 points with automatic buffer recognition
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 2 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 3 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 4 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 5 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 6 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 7 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 8 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 9 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 10 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 11 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 12 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 13 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 14 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 15 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 16 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 17
pH Calibration Procedure
  1. Pour a small quantity of pH 6.86, pH 4.00, and pH 9.18 solution into clean beakers
  2. For particularly accurate calibration, use two beakers for each buffer solution - one for rinsing the electrode and one for calibration to minimize contamination risks
  3. Switch on the instrument
  4. Immerse the electrode in pH 6.86 buffer solution and gently shake until the reading stabilizes
  5. Press the "CAL" button until the calibration indicator lights up, then press "PH7" until the display shows "6.86". Rinse the electrode with distilled water
  6. Immerse the electrode in pH 4.00 buffer solution and gently shake until the reading stabilizes
  7. Press the "CAL" button until the calibration indicator lights up, then press "PH4" until the display shows "4.00". Rinse the electrode with distilled water
  8. Immerse the electrode in pH 9.18 buffer solution and wait for the reading to stabilize until the display shows exactly 9.18
  9. The calibration of the instrument's pH range is now complete
Packing & Delivery
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 18 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 19 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 20 PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer 21
Original box gift box packaging included

전체 등급

5.0
이 공급업체에 대한 50개의 리뷰를 기반으로 합니다.

등급 스냅샷

다음은 모든 평점의 분포입니다.
5 별
100%
4 별
0%
3 별
0%
2 별
0%
1 별
0%

모든 리뷰

D
Dennis
Canada May 22.2024
good product
연락처 세부 사항
SHEN ZHEN YIERYI Technology Co., Ltd

담당자: Miss. Feng

전화 번호: +8619129364625

회사에 직접 문의 보내기 (0 / 3000)